| Sign In | Join Free | My infospaceinc.com |
|
Brand Name : XWELL
Model Number : BCDS70-05-10
Certification : CE
Place of Origin : China
MOQ : 1pcs
Price : USD 2000/pcs
Payment Terms : T/T,Western Union,L/C
Supply Ability : 100 pcs per month
Delivery Time : 15-20 days
Packaging Details : Wooden box
After-sales Service : Provided
Type : Semi-Automatic
Power supply : AC220V 50Hz
Charging Accuracy : ±(0.2% of reading +0.2% of range)
Discharge Range : 50-10000mA
Discharge Accuracy : ±(0.2% of reading +0.2% of range)
Constant Voltage Cut-off Current : Minimum 50mA
Discharge Power : ≤700W
Inspection Time : Real-time Collection<2S
Aging machine is mainly used for charging and discharging cycle test of finished lithium battery packs. The test items includes: battery charging protection voltage, discharge protection voltage, capacity, etc. It has charging, discharging, testing, and circulating 4 test steps. By editing the steps of the plan, the battery can be tested according to the set process.
Product characteristics:
♦ With PC software, USB hub, and router
♦ The computer is not configured locally, so the customer needs to buy it itself
♦ With constant current and constant pressure charging function
♦ The equipment has a constant current discharge function
♦ Fully meet the requirements of the battery pack charge and discharge outlets and charge and discharge outlets
♦ At the same time, aging positive plate can protect negative plate discharge protection
♦ By charging and discharge cycle of the battery, you can detect whether the charging protection and discharge protection of the battery are normal
♦ Charge and discharge cycle on the battery and record the charging capacity and discharge capacity
Product Specification
| Technical Parameter | ||
|
|
Measuring Range | 7-70V |
| Accuracy | ±(0.2% of reading +0.2% of range) | |
|
|
Charging Range | 50-5000mA |
| Charging Accuracy | ±(0.2% of reading +0.2% of range) | |
| Discharge Range | 50-10000mA | |
| Discharge Accuracy | ±(0.2% of reading +0.2% of range) | |
| Charge | Constant Voltage Cut-off Current | Minimum 50mA |
| Capacity | Accuracy | ±1% |
| Power | Discharge Power | ≤700W |
| Time | Inspection Time | Real-time Collection<2S |
| Timing Range | 0-999h/step | |
| Data Recording Interval | ≥5S | |
| Middle Machine Version | 1:1 series | |
| Number of Passages Per Cabinet | 12 channels, four rows and three column | |
|
Charge |
Charging Mode | Constant Current and Constant Voltage Charging |
| Cut-off condition | Voltage, Current, Relative Time, Overcharge Protection | |
| Discharge | Discharge mode | Constant current discharge |
| Cut-off condition | Voltage, Relative Time and Over-discharge Protection | |
| Loop | Cyclic measurement range | 1-999 times |
| Single cycle step number | 100 | |
| Voltage and Current Detection Sampling | Four-wire sampling | |
| Data Base | Using SQL database to manage test data | |
| Upper computer communication mode | Based on TCP/IP Protocol/Serial Port | |
| Data Output Mode | EXCEL/TXT/Chart | |
| Communication Interface | Mesh port | |
| Chassis dimensions | 300x450x170mm | |
| Cabinet size | 900x600x1900mm | |
| Spatial Dimension of Discharge Battery | 900x600x130mm | |
|
|
Battery Charge Discharge Tester Battery Aging Test Machine Images |